Standard Test Method for Compressive Strength of …
Scope. 1.1 This test method covers determination of compressive strength of cylindrical concrete specimens such as molded cylinders and drilled cores. It is limited to concrete having a density in excess of 800 kg/m 3 [50 lb/ft 3 ]. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard.
Chemical Passivation Treatments for Stainless Steel Parts1
in 1996. Last previous edition approved in 2013 as A967/A967M – 13. DOI: 10.1520/A0967-17. 2 For referenced ASTM standards, visit the ASTM website,, or contact ASTM Customer Service at [email protected]. For Annual Book of ASTM Standards volume information, refer to the standard's Document Summary page on the ASTM …
ASTM-A967 | Standard Specification for Chemical
The ASTM A967/A967-13 replaces ASTM A967/A967M-05 which is now obsolete. Keywords. cleaning of stainless steel; passivation; passivation tests; tests for cleanliness of stainless steels;; ICS Number Code 77.140.20 (Steels of high quality) To find similar documents by ASTM Volume: 01.03 (Steel--Plate, Sheet, Strip, Wire; Stainless Steel Bar)
A967 Standard Specification for Chemical
Scope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and …
ASTM International
ASTM A967/A967M-17. July 1, 2017. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types …
Chemical Passivation Treatments for Stainless Steel Parts1
in 1996. Last previous edition approved in 2013 as A967/A967M – 13. DOI: 10.1520/A0967-17. 2 For referenced ASTM standards, visit the ASTM website,, or …
Standard Test Method for Determining Interlaminar
5.3 This test method is particularly useful for electrical steels coated with inorganic insulating coatings having surface insulation resistivities in excess of 0.3 kΩ·cm 2 [30 kΩ·mm 2] when tested using Test Method A717/A717M (a Franklin current less than 0.02 A). This test method can readily be extended to any range of insulation resistivity …
A967/A967M Standard Specification for Chemical
AbstractThis specification covers several different types of chemical passivation treatments for stainless steel parts. The treatments are the following: immersion treatment using nitric acid solutions, immersion treatment using citric acid solution, and
Installation Guidance
In stainless steel, the passivation process uses nitric acid or citric acid to remove free iron from the surface. The chemical treatment leads to a protective oxide layer that is less likely to chemically react with air and cause corrosion. At Inline design the standards we follow are ASTM A967, ASTM A380 and AMS 2700.
A380 Standard Practice for Cleaning, Descaling
Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems A0380-06 ASTM|A0380-06|en-US Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems Standard A380 Standard Practice for Cleaning, Descaling, and Passivation of Stainless …
Revision of A967/A967M-17 Standard Specification for …
Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...
Passivation of Stainless Steel
* ASTM Committee A-1 on Steel, Stainless Steel, and Related Alloys * ASTM Committee on Standards 100 Barr Harbor Drive West Conshohocken, PA 19428 2. Fed. Spec. QQ-P-35C October 28, 1988 Passivation Treatments For Corrosion Resistant Steel * CANCELLED April 4, 1997 * SUPERSEDED by ASTM A 967 - 96 Copper Sulfate test per MIL-STD-753.
Metals | Free Full-Text | Corrosion Behavior of Passivated
Custom 450 stainless steel and AM 350 stainless steel are both precipitation hardening stainless steels, which are widely used in a variety of aerospace applications. The former steel exhibits very good corrosion resistance with moderate strength, whereas the latter is used for applications requiring high strength along with corrosion resistance. In …
Unpacking ASTM A967
ASTM A967/A967M – Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. This standard details effective methods to …
ステンレススチール
astm a380 astm a967 (1、2、5) qq-p-35 (タイプ ii & vi) rohs、reach、elvおよびweee の の サイズ 132インチ x 48インチ x 28インチ 20" x 30" x 9"---
ASTM A 967/A967M : 2017 | Chemical Passivation …
ASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. Language (s): English. Published date: 07-01-2017. Publisher: American Society for Testing and Materials.
ASSIST-QuickSearch Document Details
Title: Chemical Passivation Treatments for Stainless Steel Parts (Replaced by ASTM-A967/A967M) Scope: This specification covers several different types of …
Passivation ASTM A380, ASTM A967, QQ-P-35C, BS EN …
ASTM A967 - Specification for Chemical Passivation Treatments for Stainless Steel Parts (based on US Defense Department standard QQ-P-35C) 3. BS EN 2516 - Passivation of Corrosion Resisting Steels and Decontamination of Nickel Base Alloys ASTM A380 nitric acid based passivation treatments
Passivation of Corrosion Resistant Steels
AMS 2700 has no guidelines for descaling or chemical cleaning processes detailed in ASTM A380 and ASTM A967; AMS 2700 is strictly a specification on passivation processes. ASTM A967 describes a passivation procedure must follow cleaning and / or descaling. Any contamination not removed prior to passivation reduces a part's corrosion ...
Passivation of stainless steels – British Stainless Steel
Solution strengths of 4-10% citric acid are specified for passivation treatments in ASTM A967. Specifications for passivation treatments for stainless steels. Traditionally the American standards have been used. These include: – ASTM A380 – Practice for Cleaning, Descaling and Passivating of Stainless Steel Parts, Equipment and Systems
Reinigung / Passivierung – corrgo – Chemische Behandlung
Die Norm A967 beschreibt die Vorgänge bei der Passivierung und gibt verschiedene Eckpunkte vor. Eine genaue Vorgabe, welche Lösung dabei zu verwenden ist, wird darin nicht gemacht, sondern bleibt dem Anwender freigestellt. Hier hilft Ihnen die langjährige Erfahrung der CORRGO AG das optimale Medium mit den Einsatzbedingungen …
ASTM A967/A967M
:ASTM A967/A967M タイトル:Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts ステンレスのパッシベーションの は、ステンレスのについてしたものである。をいた、クエンを ...
Passivation of Stainless Steel | ASTM A967, AMS …
Specifications: ASTM A967 AMS 2700 QQ-P-35 ASTM 380 ASTM F86 AMS 2700 ISO 16048 Most Company Specifications Types: Precision Medical-Grade Passivation Commercial Passivation A-A-A …
ASTM A967/A967M : Standard Specification for Chemical …
ASTM A967/A967M, 2017 Edition, July 1, 2017 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
A967ってなに? | | めっきQ&A | サン
A967ってなに? . パッシベーションのは、QQ-P-35やA967といったのがいられます。. A967には、をとしたNitric、クエンのCitricがありますが、にのNitricは、として、のようなをしています。.
Chemical Passivation Treatments for Stainless Steel Parts
A 967 2 3. Terminology 3.1 Definition of Term Specific to This Standard—It is necessary to define which of the several commonly used definitions of the term passivation will be …
ASTM A967/A967M-17
ASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and …
Passivation of Aerospace Stainless Steel Parts with Citric …
Chemical Passivation. The chemical treatment removing the free iron from the surface of stainless steel is called passivation. The chemical used is most commonly nitric acid (HNO 3 ), a highly corrosive mineral acid. This acid was specifically called for in SAE AMS-QQ-P-35 which was the standard used throughout the aerospace industry into …
ASTM A967/A967M-13
1.6 The following precautionary caveat pertains only to the test method portions, Section 14 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory …